For monitoring centres

Alerts already verified by AI, before they ever reach you.

The IA-N box analyses every camera on-site and forwards to your centre only the real events — a person, a vehicle — over the SIA‑DCS and Contact ID protocols your receiver already knows how to read. Zero development, zero hardware to add on your side.

SIA DC-09 & Contact ID Video alarm verification AES-128 optional
IA-N box — customer siteDetects a person, filters out the noise (wind, shadows, animals)
ElectroniSafe relayBuilds the SIA-DCS / Contact ID message with your account code
Your receiving centreReceives the event on your current equipment, with nothing to install
A dedicated SIA/CID account for every boxLatency < 2 s

What it changes for you

Less noise, more service to sell.

Filtering happens before the alert ever leaves the client's site — your team only handles what truly matters.

No more false sensor alarms

The onboard AI recognises a person or a vehicle and ignores the rest (wind, leaves, headlights, animals). Your operators are only disturbed for the real thing.

Instant video alarm verification

Every event transmitted includes a secure video link, valid for 15 minutes, straight from the portal. No video receiver to buy or integrate.

Compatible with your current receiver

Standard SIA DC-09 and Contact ID (ADM-CID) frames. If your alarm panel reads them today, it will read IA-N — not a line of code on your side.

Optional AES-128 encryption

If your procedure requires it, the SIA-DCS frame can be AES-128 encrypted — enabled in one click from your account, with nothing to change on the box.

You manage your own account

A dedicated portal to change your receiving address (SIA and/or Contact ID) yourself, at any time — no ticket, no waiting on the installer.

A new service to offer

A video-verified monitoring offer to add to your catalogue, on clients already fitted with IA-N boxes — with no hardware investment on your part.

Setup

Four steps, none of them coding on your side.

01

Account created

We create your monitoring centre account on the ElectroniSafe portal, with secure access (two-factor authentication).

02

You specify your receiver

IP address/port for SIA-DCS and/or Contact ID — both if needed, editable at any time.

03

The installer selects you

From the client's box, the installer picks your centre from a list along with the protocol — the account code is generated automatically, unique to that box.

04

You receive the events

Standard frames on your existing receiver, with a video alarm verification link on demand.

Technical compatibility

Two protocols, run in parallel if needed.

Each monitoring centre account can declare a SIA-DCS address and a Contact ID address — the installer picks the right protocol box by box, without any of it changing your configuration.

Protocol 1

SIA DC-09

Structured text format, the most widespread among recent integrators.

  • Dedicated account code per box (4 to 16 characters)
  • Optional AES-128-CBC encryption
  • CRC-16/ARC, automatic retransmission on failure
Protocol 2

Contact ID (ADM-CID)

Legacy numeric format, still the reference on many receiving alarm panels.

  • Dedicated account code per box (4 digits)
  • Standard event codes (intrusion, opening/closing)
  • Compatible with existing alarm panels without an update

Several receiving centres?

Load balancing, separate regions: we create one entry per centre. Your installers find them all in the same list, with no technical juggling for you.

GDPR & privacy

You only receive what is necessary.

Footage stays stored on the box, at the client's premises. What reaches you is the event (type, zone, timestamp) in SIA/Contact ID format, plus a time-limited video review link if you need to verify the alarm — never a permanent stream, never storage on our side.

  • Alarm-verification video link that expires automatically (15 min)
  • No footage retained on our servers
  • Access to your account protected by two-factor authentication
  • Every login and action logged, timestamped and tamper-proof

Frequently asked questions

What we get asked the most.

Do we need to change our receiving equipment?

No. SIA DC-09 and Contact ID frames are standards your receiver already knows how to read. IA-N adds itself just like any other transmitter.

Who chooses each client site's account code?

It is generated automatically and assigned to each box individually — never shared between two clients, even with the same installer.

How long before we're operational?

As soon as your account is created and your receiving address is set, any installer can select you immediately from their box.

Is there a cost for the monitoring centre?

No, the connection is free for you. Your commercial model with your clients remains entirely your own.

Can we change the receiving address later?

Yes, directly from your portal, at any time — without deleting and recreating the account, without losing the history.

Account request

Let's talk about your receiving centre.

Leave us your details: we'll get back to you quickly to create your account and configure your receiving address(es) (SIA-DCS and/or Contact ID).

Reply within 48 business hours Free setup